Now the application penetration rate of LED display has been very high. When purchasing LED display, there are many calculation formulas. Only when the calculation is correct, can the best LED display be selected. Such as spacing, length and height, number of modules used, etc. But many people don't know much about this. Today, YONGS LED display will tell you about his power calculation method.
A fórmula para potência é P=UI.
P stands for power, U stands for voltage, and I stands for current. Usually, the power supply voltage we use is 5V, and the power supply is 30A and 40A; single color is 8 unit boards and 1 40A power supply, and two-color is 6 unit boards. 1 power supply; The power of the outdoor screen is very clear in the "product parameters" on the website.
Um exemplo será dado a seguir:
Uma unidade precisa fazer uma tela eletrônica interna de 5.0 duas-cor de 9 metros quadrados e calcular a potência máxima necessária. Primeiro, é muito simples calcular o número de 40fontes de alimentação A=9 (0,2440,488)/6=12.5=13 fontes de alimentação (para ser um número inteiro, o que for maior), a potência máxima P=1340A5V=2600W. A potência de uma única lâmpada=a potência de uma lâmpada 5V20mA=0.1W.
A potência da placa da unidade de exibição de LED=a potência de uma única resolução de lâmpada (o número de pixels horizontais o número de pixels verticais) / 2.
A potência máxima da tela {{0}} a resolução da tela o número de luzes por resolução 0,1.
A potência média da tela {{0}} a resolução da tela o número de luzes por resolução 0,1/2.
A potência real da tela {{0}} a resolução da tela o número de luzes por resolução 0,1 / o número de varreduras (4 varreduras, 2 varreduras, 16 varreduras, 8 varreduras, estática).